Your fire alarm
The existing panel provides alarm, supervisory and trouble outputs, where available.
Fire Alarm Monitoring VANCOUVER ISLAND
A clear connection between your building’s fire alarm and a monitoring centre. Carefully planned, professionally connected and tested with your fire alarm contractor.
Mid-Island based. Serving Vancouver Island.

THE CONNECTION THAT MATTERS
Your fire alarm system detects and signals conditions within the building. Monitoring equipment sends the available signals to a receiving centre, where operators follow the response procedures agreed for your property.
The existing panel provides alarm, supervisory and trouble outputs, where available.
Compatible equipment transmits signals over the selected communication path.
Operators follow the property’s procedures for emergency and building-contact notifications.
Sherwood handles the monitoring connection. Fire alarm installation, inspection, maintenance and repairs remain with your qualified fire alarm contractor.
DIFFERENT SIGNALS. CLEAR NEXT STEPS.
An alarm, a condition needing attention and an equipment fault are different events. We plan the interface so the receiving centre can distinguish the available signal types.
The panel reports an alarm, which may originate from detection, a pull station or sprinkler waterflow, depending on the system.
ResponseThe monitoring centre follows the property’s fire response procedures, including notifying emergency services as required.
A monitored fire protection condition is outside its normal state—for example, a sprinkler valve supervisory condition.
ResponseThe designated contacts are notified according to the agreed instructions for the property.
The panel reports a fault, such as a power, battery or circuit issue. Monitoring communication faults are also considered in the design.
ResponseThe appropriate contacts are notified so the responsible service company can investigate.
The detail received depends on the interface. Common alarm, supervisory and trouble outputs may identify the category without identifying the individual device or its location.

A CONNECTION DESIGNED FOR YOUR SITE
We assess equipment compatibility, cellular coverage, network reliability and backup power before proposing a communication arrangement.
A suitable communicator sends signals over the mobile network. Coverage and antenna position matter.
A compatible connection uses the building’s wired internet service. Supporting network equipment and backup power are reviewed.
Compatible IP and cellular paths can provide redundancy. Supervision, failure reporting and power are planned together.
The receiving equipment checks that the communication arrangement is operating as intended. Active and passive arrangements use different approved methods, test transmissions and failure-reporting settings. The correct arrangement depends on the applicable requirements, equipment listing and receiving centre.
BEHIND THE CONNECTION
Professional monitoring combines the building’s signals with current contact information and a defined response plan.
We coordinate signal testing, confirm the event categories received and help establish a clear handover for the property and its service team.

FOR FIRE ALARM COMPANIES & ELECTRICAL CONTRACTORS
Need someone to connect monitoring for a customer’s building? Bring Sherwood into the conversation early so the interface, equipment and commissioning can be coordinated with your work.

Review panel outputs, the monitoring interface, equipment location, communication requirements and any certificate requirements before installation.
Agree who handles each part of the work, site access, the monitoring account and the test window with the building representative.
Coordinate alarm, supervisory, trouble and restoration tests as applicable. Confirm signal receipt and explain who to contact for monitoring support or fire alarm service.
Tell us at the enquiry stage. We confirm the applicable CAN/ULC-S561 requirements and the responsible providers before defining the scope. A listed product or monitoring centre alone does not certify the complete installation. Site certificates must be issued through an appropriately ULC Listed company.
About the ULC certificate program ↗
EXISTING BUILDING. NEW MONITORING PLAN.
Start with a review of the existing equipment, contract and communication service. We assess whether the current connection can be retained or needs upgrading.
Coordinate the changeover and signal testing before the old monitoring service or telephone connection is cancelled.
Discuss your fire monitoring changeover ↗BEFORE WE GET STARTED
No. Sherwood’s scope here is the monitoring connection and associated monitoring equipment. Fire alarm panels, detectors, pull stations, horns, strobes, inspections and fire alarm repairs remain with your qualified fire alarm contractor.
Yes. We can coordinate connection planning and monitoring signal tests with your fire alarm contractor. The equipment, interface, responsibilities and scheduling are agreed for the project.
No. Requirements depend on the building and applicable requirements from the authority having jurisdiction, insurer or project specification. Communication paths, supervision and any certificate requirement need to be confirmed for the property.
Send the property address, building use, panel make and model, existing monitoring details, any drawings or written requirements and your fire alarm contractor’s contact. Include the target date and any certificate requirement. Please leave passwords and access codes out of the enquiry.
LET’S PLAN THE CONNECTION
For property owners, managers and fire alarm companies across Vancouver Island.